Settings
The Settings page in DR Sim Manager allows you to configure general behavior, keyboard shortcuts, motion parameters, safety limits, audio notifications, kiosk mode, remote control, and user interface preferences. This guide provides detailed descriptions of every configurable option.
General
Section titled “General”Refresh Rate:
Section titled “Refresh Rate:”- Description: Sets the interval (in milliseconds) at which the motion processing loop runs and sends data to the motion simulator. Lower values mean higher update frequency. A value of 2 ms corresponds to a 500 Hz motion loop.
- Range: 1 – 20 ms
- Default: 2 ms (500 Hz)
Log Verbosity:
Section titled “Log Verbosity:”- Description: Controls the level of detail written to the application log. Higher verbosity captures more diagnostic information, which can be helpful for troubleshooting. Lower verbosity reduces log noise during normal use.
- Options: DEBUG, INFO (default), WARNING, ERROR, CRITICAL
- Default: INFO
Process Priority:
Section titled “Process Priority:”- Description: Sets the Windows process priority for DR Sim Manager. Higher priority may improve motion responsiveness by reducing scheduling delays, but can affect overall system performance.
- Options: Normal, Above Normal, High
- Default: High
Minimize to System Tray:
Section titled “Minimize to System Tray:”- Description: When enabled, closing the main window minimizes DR Sim Manager to the system tray instead of exiting the application. You can restore it by clicking the tray icon.
- Default: Disabled
Launch Minimized:
Section titled “Launch Minimized:”- Description: When enabled, DR Sim Manager starts minimized — either to the system tray (if Minimize to System Tray is also enabled) or to the taskbar. Useful for setups where the application should run in the background on startup.
- Default: Disabled
Check for Updates:
Section titled “Check for Updates:”- Description: When enabled, DR Sim Manager automatically checks for new versions once per day on startup. If a new version is found, a dialog will appear with a Download button (opens the releases page in your browser) and a Later button to dismiss. You can also check manually at any time from the right-click context menu.
- Default: Enabled
Source List:
Section titled “Source List:”- Description: Opens the list of games. Allows users to favorite or hide sources.
- Action: Click on
Editto modify the source list.
Send Anonymous Usage Data:
Section titled “Send Anonymous Usage Data:”- Description: When enabled, DR Sim Manager sends anonymous crash reports and usage statistics to help improve the application. No personal data is collected — see the Privacy Policy for full details. Disabling this completely stops all telemetry transmission.
- Default: Enabled
Create Debug Report:
Section titled “Create Debug Report:”- Description: Generates a comprehensive debug report for troubleshooting purposes. The report includes system information, GPU details, current settings, simulator configuration, output configuration, profile configuration, and recent log entries. See Creating a Debug Report for full details.
- Action: Click the button and choose a save location.
Reset to Defaults:
Section titled “Reset to Defaults:”- Description: Resets all settings on this page back to their factory default values. This does not affect profiles, sim config, or output configurations.
- Action: Click the Reset to Defaults button.
Audio Notifications
Section titled “Audio Notifications”These checkboxes enable or disable sound alerts for specific events during motion:
- Safety Filter — Plays a sound when the safety filter activates due to a motion spike exceeding the configured thresholds. Useful for tuning — you can hear when spikes are being caught without watching the log.
- Axis Overallocation — Plays a sound when one or more axes are overallocated (i.e., cue outputs exceed the available axis travel).
- Crash Detection — Plays a sound when a crash is detected in the game.
All audio notifications are disabled by default.
Keyboard Shortcuts
Section titled “Keyboard Shortcuts”Keyboard shortcuts allow you to control DR Sim Manager without switching to its window. Each action can have both a keyboard shortcut and a controller button assigned.
- Set: Binds a keyboard shortcut or controller button.
- Clear: Unbinds a keyboard shortcut or controller button.
For the full list of available shortcuts, see Keyboard & Controller Shortcuts.
Motion
Section titled “Motion”Global Gain:
Section titled “Global Gain:”- Description: Adjusts the overall intensity of the motion. This scales all motion output proportionally. Can also be adjusted via keyboard or controller shortcuts.
- Range: 0.00 – 1.00
- Default Value: 1.00
Input Gain:
Section titled “Input Gain:”- Description: Adjusts the strength of the incoming telemetry signal before it is processed. Lowering this value reduces the overall input intensity, which can help tame aggressive telemetry data from certain games. Can also be adjusted via keyboard or controller shortcuts.
- Range: 0.00 – 1.00
- Default Value: 1.00
Soft Axis Travel Limits:
Section titled “Soft Axis Travel Limits:”- Description: When enabled, this option limits the motion on all axes to prevent abrupt stopping when hitting the limit of an axis. Instead of a hard stop, motion smoothly decelerates as it approaches the travel limit. This is automatically disabled when using the Manual Control source.
- Default: Enabled
Start Motion In Paused State:
Section titled “Start Motion In Paused State:”- Description: When enabled, motion starts in a paused state whenever you press Start. The simulator will move to its home position but will not respond to game telemetry until you manually resume. This is useful if you want to verify everything is connected before allowing motion.
- Default: Disabled
Safety
Section titled “Safety”Safety Filter Activation Thresholds
Section titled “Safety Filter Activation Thresholds”The safety filter monitors each axis independently and intervenes when acceleration exceeds a configurable threshold. For a detailed explanation of how this works and how to tune it, see Spike Filtering.
Translational Axes:
Section titled “Translational Axes:”- Description: Sets the acceleration threshold for triggering the safety filter on translational axes (surge, sway, heave) based on G-force. When acceleration on any translational axis exceeds this threshold, the filter activates on that axis only.
- Range: 0.10 – 50.00 Gs
- Default Value: 3.00 Gs
Rotational Axes:
Section titled “Rotational Axes:”- Description: Sets the acceleration threshold for triggering the safety filter on rotational axes (pitch, roll, yaw) based on angular acceleration. When acceleration on any rotational axis exceeds this threshold, the filter activates on that axis only.
- Range: 100 – 50000 °/s²
- Default Value: 2000 °/s²
Crash Detection
Section titled “Crash Detection”Crash detection monitors game telemetry for sudden impacts and can automatically respond to protect the user and equipment. This is a separate feature from spike filtering — see Spike Filtering for the difference.
Aircraft/Flight Vehicles:
Section titled “Aircraft/Flight Vehicles:”- Description: Controls what happens when a crash is detected in a flight game.
- Options:
- Auto (default) — Automatically determines the best response based on the crash severity.
- Pause Motion — Pauses motion output when a crash is detected.
- Disabled — No special action is taken on crash.
Cars/Ground Vehicles:
Section titled “Cars/Ground Vehicles:”- Description: Controls what happens when a crash is detected in a driving/racing game.
- Options:
- Auto (default) — Automatically determines the best response based on the crash severity.
- Pause Motion — Pauses motion output when a crash is detected.
- Disabled — No special action is taken on crash.
Source Data Limits
Section titled “Source Data Limits”Setting these limits clamps incoming telemetry to prevent large motion spikes from occurring during extreme conditions in-game. This is applied before the safety filter.
Acceleration:
Section titled “Acceleration:”- Description: The acceleration telemetry data from the selected game is clamped to stay below this value. Applies to all vehicle types.
- Range: 1.00 – 100.00 m/s²
- Default Value: 30.00 m/s²
Angular Velocity:
Section titled “Angular Velocity:”- Description: The angular velocity telemetry data from the selected game is clamped to stay below this value. This value only affects flight games.
- Range: 1 – 1000 °/s
- Default Value: 180 °/s
Remote Control
Section titled “Remote Control”The Remote Control Interface (RCI) lets you control DR Sim Manager from any device on your local network. For full details, see Remote Control.
Enable Remote Control Interface:
Section titled “Enable Remote Control Interface:”- Description: Enables or disables the Remote Control Interface server. When enabled, a WebSocket server starts and allows connections from other devices on your network.
- Default: Disabled
- Description: Sets the connection protocol.
- Options: HTTPS (default), HTTP
- Default: HTTPS
Remote Control Port:
Section titled “Remote Control Port:”- Description: The network port the server listens on.
- Range: 1024 – 65535
- Default: 8000
Require Password:
Section titled “Require Password:”- Description: When enabled, connecting devices must enter a password to access the remote control interface.
- Default: Disabled
Set Password:
Section titled “Set Password:”- Action: Click Set to create or change the remote control password.
User Interface
Section titled “User Interface”UI Font Size:
Section titled “UI Font Size:”- Description: Adjusts the font size used throughout the user interface. Changes take effect immediately.
- Range: 6 – 16
- Default Value: 8
Theme:
Section titled “Theme:”- Description: Sets the visual theme of the software interface. Changes take effect immediately.
- Options: Dark (default), Light, Classic
- Default: Dark
Show UI Docks:
Section titled “Show UI Docks:”Buttons that toggle the visibility of each dock panel. For detailed information on each dock, see Docks & Visualizers.
- Source Data: Opens the dock for viewing raw telemetry data received from the selected game.
- Debug Log: Opens the dock for viewing the live debug log, useful for troubleshooting.
- Sim Position: Opens the dock for monitoring the simulator’s position in real-time via gauges.
- Manual Control: Opens the dock for manually controlling each axis of the motion simulator.
- Sim Visualization: Opens the 3D visualizer dock showing a live model of your simulator.
- Gain Display: Opens the gain display dock for viewing real-time gain values.
Working with Docks
Section titled “Working with Docks”Docks can be rearranged within the main window by dragging their title bars. You can also drag a dock out of the main window to make it a floating panel — drag it back to redock it.
Right-click context menu: Every dock has a consistent right-click menu on its title bar with the following options:
- Always On Top — Keep the dock above other windows.
- Browse Profiles — Open the Profiles folder.
- Browse Plugins — Open the Plugins folder.
- Open Log — Open the log file location.
- Help — Open the online documentation.
- Check for Updates… — Manually check for a newer version of DR Sim Manager.
- Announcements — View the latest announcements.
- About — Show application info.
- Manage License… — View and manage your license. Depending on your current state, this opens the license management window or the activation dialog. See Licensing & Activation.
- Convert to Window / Convert to Dock — Switch between dock and independent window mode (see below).
- Close Dock — Close the dock panel.
Some docks also have additional actions at the top of the menu. For example, the 3D Visualizer includes a Camera View submenu, and the Gain Display includes options to Increase Size, Decrease Size, and Reset Size.
Independent windows: If you want a dock to behave as a fully independent window (with its own taskbar entry that can be minimized and restored separately from the main window):
- Right-click the dock’s title bar and select “Convert to Window”.
- The dock becomes a standalone window with its own taskbar entry.
- To return it to the dock system, right-click the window’s title bar and select “Convert to Dock”.
Closing a detached window automatically returns it to the dock system. This is especially useful for multi-monitor setups where you want to keep certain panels visible on a separate screen independently of the main window.
Kiosk Mode
Section titled “Kiosk Mode”Kiosk Mode simplifies the interface for shared or public setups. For full details, see Kiosk Mode.
All Settings Reference
Section titled “All Settings Reference”The table below lists every setting, its default value, and the section where it appears in the Settings tab.
| Setting | Default Value | Section |
|---|---|---|
| Refresh Rate | 2 ms (500 Hz) | General |
| Log Verbosity | INFO | General |
| Process Priority | High | General |
| Minimize to System Tray | Disabled | General |
| Launch Minimized | Disabled | General |
| Check for Updates | Enabled | General |
| Send Anonymous Usage Data | Enabled | General |
| Safety Filter Audio | Disabled | Audio Notifications |
| Overallocation Audio | Disabled | Audio Notifications |
| Crash Detection Audio | Disabled | Audio Notifications |
| Global Gain | 1.00 | Motion |
| Input Gain | 1.00 | Motion |
| Soft Axis Travel Limits | Enabled | Motion |
| Start Motion In Paused State | Disabled | Motion |
| Translational Threshold | 3.00 Gs | Safety |
| Rotational Threshold | 2000 °/s² | Safety |
| Aircraft Crash Behavior | Auto | Safety |
| Car Crash Behavior | Auto | Safety |
| Source Data Accel Limit | 30.00 m/s² | Safety |
| Source Data Angular Vel Limit | 180 °/s | Safety |
| Enable Remote Control | Disabled | Remote Control |
| RCI Mode | HTTPS | Remote Control |
| RCI Port | 8000 | Remote Control |
| RCI Require Password | Disabled | Remote Control |
| UI Font Size | 8 | User Interface |
| Theme | Dark | User Interface |
| Kiosk Mode | Disabled | Kiosk Mode |
| Kiosk Password Protection | Disabled | Kiosk Mode |
| Launch in Kiosk Mode | Disabled | Kiosk Mode |
Remote Control
Section titled “Remote Control”The Remote Control Interface lets you control DR Sim Manager from another device over your network. For full details, see Remote Control.
Generate Debug Report
Section titled “Generate Debug Report”At the bottom of the Settings page, the Generate Debug Report button creates a diagnostic report containing your current settings, system information, and log data. This is useful when reporting issues or asking for support.
When clicked, you can choose to:
- Copy to Clipboard — Copies the report text so you can paste it directly into a Discord message or support ticket.
- Save to File — Saves the report as a
.txtfile to a location of your choice.
Reset to Defaults
Section titled “Reset to Defaults”Description: Resets all settings on this page to their default values.